Pharma clean room supplier in China: Settling colony count and plankton determination requirements: at the same time of each experiment, count the settling colony of microorganisms in the operating room and laminar flow table, record the results in the user log, and record the original data of the experimental environment in the experiment report. Disinfection requirements: Every week and every operation in the sterile room, the operating table and the dead corners should be wiped with appropriate disinfectant. The specific method is to use sterile gauze impregnation disinfection solution to clean the entire inner surface of the super clean bench, and aseptic room, flow of people, logistics, buffer room floor, transfer window, door handle. Cleaning and disinfection procedures should be from the inside out, from high clean areas to low clean areas. Gradually exit the clean area. Then turn on the aseptic air filter and UV lamp for 1-2h sterilization to kill the remaining microorganisms. At the end of each operation, wipe the workbench with the above disinfection solution, remove indoor moisture, and sterilize with UV lamp for 30min. Read extra info at tablet press dies.
Tablet press is mainly used for tablet technology research in pharmaceutical industry. The tablet pressing machine presses powder or granular raw materials into tablets. Its scope of application: Traditional Chinese medicine, western medicine, health products, food, chemical industry, electronics and other industries. The prefabricated container house is a new concept of environmentally friendly and economical house with light steel H-shaped steel and channel steel as the framework, sandwich panel as the wallboard material, space combination with standard modulus series, and bolted or welded components.
The filling speed of the capsule filling machine is fast, and the size difference of the capsule filling machine is small. It integrates the powder capsule shell finishing, capsule cap finishing and capsule package, which is compact and convenient. In addition, the capsule filling machine has many advantages, such as fast arrangement speed, high efficiency, simple operation, convenient maintenance and low power consumption. It is the preferred capsule filling (filling) machine for pharmaceutical factories, health product factories, hospital preparation rooms, etc
Use a Hygrometer: A hygrometer is a device that measures the current humidity level in the room. By regularly monitoring the cleanroom humidity control with a hygrometer, you can identify any fluctuations and take corrective action if necessary. Ventilation: Proper ventilation is crucial for maintaining healthy humidity levels in clean rooms. Ensure that there are sufficient exhaust fans in place to remove excess moisture and carbon dioxide from the air. Additionally, consider installing temperature and humidity sensors to monitor changes in the environment and adjust ventilation accordingly. Control Water Sources: Closely monitor water sources within the clean room, such as sinks or taps, as they can contribute to high humidity levels. Be sure to turn off faucets when not in use and avoid running water unnecessarily.
Mainly control the pollution of air dust particles and organisms (bacteria) to working objects, and maintain a negative pressure with the atmosphere inside. Pharma cleanroom project It is suitable for precision machinery industry, electronics industry, aerospace industry, high-purity chemical industry, atomic energy industry, optomagnetic product industry, LCD, computer hard disk; pharmaceutical industry, hospital, operating room, sterile ward, food, cosmetics, beverage products Animal laboratory, physical and chemical laboratory, blood station, etc. More cases check our cleanroom project page.
The detection of air volume and wind speed must be carried out first, and all effects of purified air conditioning must be obtained under the designed air volume and wind speed. Before air volume detection, it is necessary to check whether the fan operates normally, whether all components in the system are installed correctly and whether there are obstacles (such as whether the filter is blocked or blocked). All valves should be fixed at a certain opening position, and the size of the measured air outlet and air duct must be measured. For the turbulent flow clean room, the air supply volume shall be determined by the air outlet method or air duct method. See Item 6, 7 and 8 respectively. For the air outlet without filter, the method in Appendix I of the current national standard code for construction and acceptance of ventilation and air conditioning engineering (gbj243) can be implemented.
Suzhou Pharma is one of the leading turnkey project providers for pharmaceutical, food, herbal, cosmetic, electronics factory and chemical plants. We offer projects as per GMP regulations. As being pioneers in this field, the solutions from Suzhou Pharma is readily accepted by the customers. Our solid expertise in cleanroom allows meeting the precise needs of its customer’s industry in different sectors such as health,pharmaceutical, biotechnology, and cosmetics. We firmly believe in the principle of quality by design. Discover additional information at https://www.sz-pharma.com/.
Tablet punches and dies factory 2024: Today (Suzhou Pharma Machinery Co., Ltd.) will introduce to you, clean room airflow and influencing factors. There are many factors affecting the airflow in the clean room, such as process equipment, personnel, clean room assembly materials, lighting fixtures, etc. At the same time, the distribution point of airflow above the production equipment should also be considered.
A clean room refers to the removal of particulates, harmful air, bacteria and other pollutants in the air within a certain space, and the indoor temperature, cleanliness, indoor pressure, airflow speed and airflow distribution, noise vibration and lighting, Static control is within a certain demand range, and a specially designed room is given. That is to say, no matter how the external air conditions change, the interior can maintain the characteristics of cleanliness, temperature, humidity and pressure that were originally set. The main function of the clean room is to control the cleanliness and temperature and humidity of the atmosphere that the product comes into contact with, so that the product can be produced and manufactured in a good environmental space. We call such a space a clean room.